Racold Heat Pump Water Heater
Models: 200 L / 300 L / 500 L (split type)
A split heat pump that moves heat from the air into your water tank, in 200, 300 and 500 L sizes.
We don't list prices online — every installation is different. Tell us about your home and we'll share a written quotation after a free survey.
- Split design with outdoor heat pump unit and separate storage tank
- Three capacities: 200, 300 and 500 litres
- Quick heating option runs the heat pump and the heating element together
- Magnesium anode helps protect the tank against corrosion
- Titanium enamel coating on the tank for tough water conditions
- Isolated condenser built to European safety standards
- High efficiency compressor for faster heat exchange
- Controller for temperature setting and shower scheduling; a wired remote is now offered
- CFC-free refrigerant system
- Warranty of 5 years on the inner tank and compressor, 2 years on the product (conditions apply)
Overview
A heat pump water heater works like an air conditioner in reverse. An outdoor unit draws heat from the surrounding air and passes it to the water in an indoor storage tank, so most of the energy comes from the air rather than from the electric supply.
The Racold range is a split design: a compact outdoor unit connects to a separate storage cylinder. It comes in three tank sizes, which makes it suitable for a large family home at one end and for hostels, guest houses or small commercial kitchens at the other.
A built-in electric heating element can run alongside the heat pump when you need hot water quickly, and the controller lets you set the temperature and plan shower times.
A good fit for
- Large independent houses with several bathrooms
- Hostels, PGs and guest houses
- Hotels, resorts and small commercial kitchens
- Homes with space for an outdoor unit and good airflow
- Households looking to lower electricity use for hot water
Key specifications
- Configuration
- Split (outdoor unit + storage tank)
- Capacities
- 200 L / 300 L / 500 L
- CoP (as rated)
- 4.25 (200 L, 300 L); 4.40 (500 L)
- Highest water pressure
- 8.5 bar (200 L, 300 L); 8 bar (500 L)
- Backup heating element
- 2 kW (200 L); 3 kW (300 L, 500 L)
- Refrigerant
- R134A (200 L); R410A (300 L, 500 L)
- Max temperature, with heating element
- 75 °C (200 L); 70 °C (300 L, 500 L)
- Max temperature, heat pump mode
- 55 °C (300 L, 500 L)
- Anode
- Magnesium
- Electrical supply frequency
- 50 Hz
- Noise at 1 m
- 50 dB (200 L, 300 L); 54 dB (500 L)
- Warranty
- Inner tank 5 yrs, compressor 5 yrs, product 2 yrs
Racold heat pump water heater - technical parameters (tested at ambient 20 °C DBT / 15 °C WBT, water 15 °C to 55 °C)
| Parameter | 200 L | 300 L | 500 L |
|---|---|---|---|
| Configuration | Split | Split | Split |
| CoP | 4.25 | 4.25 | 4.40 |
| Highest water pressure (bar) | 8.5 | 8.5 | 8 |
| Heating element (kW) | 2 | 3 | 3 |
| Refrigerant | R134A | R410A | R410A |
| Tank net weight, empty (kg) | 70 | 90 | 110 |
| Tank dimensions (mm) | Ø500 x 1716 | Ø620 x 1655 | Ø733 x 1820 |
| Outdoor unit net dimensions (mm) | 780 x 300 x 543 | 780 x 300 x 543 | 975 x 420 x 603 |
| Max temperature with heating element (°C) | 75 | 70 | 70 |
| Max temperature, heat pump mode (°C) | - | 55 | 55 |
| Rated hot water output (L per hour) | 75 | 110 | 135 |
| Power output (W) | 3500 | 5261 | 6200 |
| Power input (W) | 823 | 1239 | 1409 |
| Noise at 1 m (dB) | 50 | 50 | 54 |
Specifications are summarised from the manufacturer's published literature and may change. Please confirm the exact model with us before ordering.
Please note: The leaflet quotes up to 70% lower electricity use and a 4.40 CoP. The 4.40 figure is for the 500 L model only, and the savings figures come from the manufacturer's lab test conditions. Actual savings depend on usage, climate and tariff.
Choosing the right size
- 200 L generally suits a family home with a few bathrooms; 300 L suits larger households or a small hostel.
- 500 L is aimed at heavier, repeated demand such as hostels, hotels or kitchens; it also carries the leaflet's best CoP rating.
- Hot water output per hour is listed (75, 110 and 135 L/h) - check it against your peak morning demand, not only the tank size.
- The outdoor unit needs open space with free airflow; the 500 L unit is physically larger (975 x 420 x 603 mm).
- Mind Power can check your terrace or utility area and daily hot water use before recommending a size.
Racold Heat Pump Water Heater: FAQs
How does a heat pump heat water without much electricity?
It uses electricity mainly to run a compressor and fan that move heat from the outside air into the tank, rather than creating heat directly. The more heat it moves per unit of electricity, the higher its CoP.
What does the 4.40 badge mean?
It is the Coefficient of Performance (CoP). The leaflet's footnote says this figure applies only to the 500 L model under lab test conditions. The 200 L and 300 L models are rated at 4.25 in the technical table.
Can I get hot water quickly on a cool or rainy day?
Yes. The quick heating option runs the electric heating element together with the heat pump, so you get hot water sooner than with the heat pump alone.
Where does the outdoor unit go?
It needs an open, ventilated spot such as a terrace, balcony or utility yard, connected to the tank by refrigerant piping. Mind Power can survey the site before installation.
What warranty is mentioned in the leaflet?
The leaflet lists 5 years on the inner tank and compressor and 2 years on the product. Terms and conditions apply, so confirm the details when ordering.
More heat pump water heaters
View allNot sure what you need? We will come and check.
Book a free site survey anywhere in Ballari. We look at your roof, water source, usage and power situation, then recommend the right system and share a written quotation.